Development of ultraviolet reactor (UV AOP) and optimal operation control system

goal

  • Localization of UV AOP system through CFD modeling program development and performance verification

Research Content

  1. Development of optimal design/performance prediction technique for UV reactor through CFD modeling (Patent: WO2016159420/KR101584978)
  2. Securing technological prowess and price competitiveness equal to or higher than that of foreign products
  3. Establishment of automatic control system according to fluctuations in flow rate and water quality

CFD Modiling

UV AOP reactor design

-UV AOP reactor flow analysis
-Dose Calculation
-Reactor design and performance prediction through CFD and calculation program




TEST

Derivation of CFD Modeling Parameter
CFD Modeling result verification
UV AOP reactor performance evaluation

-Performance evaluation of UV AOP System using odor and taste substances (2-MIB)
-Implementing accurate performance verification through CBD test and demonstration scale test
-Goal: Remove 2-MIB 70% and maintain hydrogen peroxide injection amount less than 10mg/L

Operating program

UV AOP reactor optimal
Control program development

-Real-time response to flow rate and water quality conditions
-Real-time online monitoring system construction
-HMI configuration based on user convenience



K-water Pilot Test 설비
Pilot Test Data VS. CFD Modeling Data